Buehler BA 1LT Zirconia Oxygen Analyser

  • Low energy consumption
  • Not temperature dependent
  • 4 – 20 mA output signal
  • No zero drift
  • High measuring accuracy
  • Long life
  • Versatile
  • No reference gases required
  • No calibration gases required

Buehler BA 2000 Oxygen Flue Gas Analyser

  • Fast response time
  • Tool-less filter change
  • Easy handling
  • Flue gas temperatures up to 1600 °C / 2912 °F
  • Durable ZrO2measuring cell
  • Display with O2measurements
  • 4-20 mA output signal
  • Ambient temperature -20 to +70 °C respectively 4 to 158 °F
  • No reference glass required
  • No test gas required
  • No gas conditioning required
  • Calibration with instrument air

Buehler BA 4000 Oxygen Headspace Analysis

  • Paramagnetic cell measuring principle
  • Long measuring cell life O2 analysis in modified atmosphere packaging
  • Easy to use
  • Quick, accurate and reliable O2 analysis
  • Optional pressure gauge

Buehler BA 4510 Portable O2 Analyser

  • calibration- and virtually drift-free measuring cell
  • 4 - 20 mA output signal
  • RS 232 interface
  • internal, switchable pump
  • easy to navigate menu
  • programmable limits
  • no test gas required

Buehler BA 5000 Gas Analyser for IR-Sensitive Gases and Oxygen

  • Sturdy 19” sheet steel housing
    Option: Desktop version with handles
  • NAMUR-based operation
  • Quick and easy parametrisation and setup
  • AUTOCAL with ambient air for virtually maintenance-free operation
  • Adjustment with test gas only required every six to twelve months depending on application
  • Large backlit LCD screen
  • Two measuring ranges per component
  • Automatically corrects fluctuations in barometric pressure
  • Monitors the sample gas flow rate
  • Two programmable limits
  • Three binary inputs
  • Eight relay outputs
  • Up to four analogue outputs 4-20 mA, electrically isolated
  • RS 485

Buehler BA3 Multi Component Gas Analyser

  • Up to three separate gas paths O2measurement paramagnetic, electrochemical and/or ZrO2
  • Modular, easy to maintain design
  • User-friendly touch screen
  • All relevant limit- and status alarms
  • Optional: Graphic on-screen flow display
  • Optional: Up to three float flow meters
  • Optional: Up to three built-in pumps
  • Optional: Pressure- and temperature compensation

Buehler Denox-MB Sample gas probe

  • Heated probe with downstream filter inside GfP housing
  • The downstream filter can easily be removed by turning the handle 90°
  • Adjustable up to 280 °C with Pt100
  • For dust loads up to 2 g/m³
  • This probe is not suitable for use in Ex areas
  • Built-in glass bead receptacle

Buehler ECO Sample gas probe

  • Unheated
  • Base unit with in-situ filter
  • With 24 VDC solenoid valves
  • With 2L compressed air tank volume
  • Including flange seal and screws

Buehler GAS 222.10 ANSI/CSA Sample gas probe

  • Unheated
  • Base unit
  • Flange seal included

Buehler GAS 222.10 Sample gas probe

  • Unheated probe with outlet filter for indoor installation.
  • The filter element can easily be removed by turning the handle 90°.
  • For dust loads up to 2g/m³, non-condensable gases.
  • The probe has no innate ignition source and is therefore suitable for use in Ex areas.
  • Base unit
  • Including flange seal and screws

Buehler GAS 222.11 ANSI/CSA Sample gas probe

  • Unheated
  • Base unit with manual shut-off valve
  • For in-situ and outlet filters
  • With blowback connection
  • Flange seal included

Buehler GAS 222.11 Ex2 Sample gas probe

  • Versions with Atex and IECEx approval
  • Unheated probe with shut-off valve and/or inlet filter
  • The filter element can easily be removed by turning the handle 90°
  • For dust loads up to 2 g/m³, non-condensable gases.
  • Combined with inlet filter up to 10 g/m³ and higher
  • The probe is suitable for use in explosive areas

Buehler GAS 222.11 Sample gas probe

  • Unheated
  • Base unit with manual shut-off valve
  • For in-situ and outlet filter
  • With blowback connection
  • The outlet filter can easily be removed by turning the handle 90°.
  • For dust loads up to 2g/m³, non-condensable gases. Combined with inlet filter up to 10g/m³ and higher
  • Including flange seal and screws

The probe has no innate ignition source and is therefore suitable for use in Ex areas.

Buehler GAS 222.15 ANSI/CSA Sample gas probe

  • Heated 180 °C / 356 °F
  • 115/230 V
  • Base unit
  • With self-regulating heater
  • Low temperature alarm 140 °C / 284 °F
  • Insulation
  • Flange seal included

Buehler GAS 222.15 MA Sample gas probe

  • Heated probe with downstream filter
  • The downstream filter can easily be removed by turning the handle 90°.
  • Increased degree of protection (IP66) due to the specially developed silicone protective cover
  • Particularly suitable for use in high-vibration applications (such as marine) due to special design features
  • The probe body and the area around the screw connection for the heated sample gas line are completely insulated
  • Self-regulating heater to approx. 180 °C with low temperature alarm.
  • For dust loads up to 2 g/m³

Buehler GAS 222.15 Sample gas probe

  • Heated 180 °C / 355 °F
  • 115/230 V
  • Base unit
  • With self-regulating heater
  • Low temperature alarm 140 °C / 285 °F
  • Insulation
  • Including flange seal and screws

Buehler GAS 222.17 ANSI/CSA Sample gas probe

  • Heated 180 °C / 356 °F
  • 115/230 V
  • Base unit
  • With weather hood
  • With self-regulating heater
  • Low temperature alarm 140 °C / 284 °F
  • Insulation
  • Flange seal included

Buehler GAS 222.17 Sample gas probe

  • Heated 180 °C
  • 115/230 V
  • Base unit
  • With weather hood
  • With self-regulating heater
  • Low temperature alarm 140 °C
  • Insulation
  • Including flange seal and screws

Buehler GAS 222.20 AMEX Sample gas probe

  • Heated to 70 °C/ 158 °F at Ta = -20 °C / -4 °F
  • 115/230 V
  • C-US and CSA approved Cl. I, Div. 2 Gps. BCD
  • Base unit
  • With weather hood
  • Heater with electronic regulator
  • Limit outputs
  • Insulation
  • Incl. flange seal

Buehler GAS 222.20 ANSI/CSA Sample gas probe

  • Heated, temperature adjustable up to 200 °C / 392 °F
  • 115/230 V
  • Base unit
  • With weather hood
  • Heater with electronic regulator
  • Limit outputs
  • Insulation
  • Flange seal included