In many applications gas analysis is key for safe and efficient control of process flows, environmental protection, and quality assurance. In extractive gas analysis the location of the gas sampling point is crucial for the reproducibility and accuracy of the analysis results. The specific filter capacity, corrosion resistance and functional equipment requirements for the probe arise from the composition of the sample gas. However, operating costs are also an important criterion in the selection, as the sampling points are frequently located at hard to access points in the system. The design of the GAS 222.15-MA is particularly suited for marine applications.
Buehler GAS 222.15 MA Sample gas probe
- Heated probe with downstream filter
- The downstream filter can easily be removed by turning the handle 90°.
- Increased degree of protection (IP66) due to the specially developed silicone protective cover
- Particularly suitable for use in high-vibration applications (such as marine) due to special design features
- The probe body and the area around the screw connection for the heated sample gas line are completely insulated
- Self-regulating heater to approx. 180 °C with low temperature alarm.
- For dust loads up to 2 g/m³
Category: Sample Gas Probes
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Related products
Buehler GAS 222.11 Ex2 Sample gas probe
- Versions with Atex and IECEx approval
- Unheated probe with shut-off valve and/or inlet filter
- The filter element can easily be removed by turning the handle 90°
- For dust loads up to 2 g/m³, non-condensable gases.
- Combined with inlet filter up to 10 g/m³ and higher
- The probe is suitable for use in explosive areas
Buehler BA 5000 Gas Analyser for IR-Sensitive Gases and Oxygen
- Sturdy 19” sheet steel housing
Option: Desktop version with handles - NAMUR-based operation
- Quick and easy parametrisation and setup
- AUTOCAL with ambient air for virtually maintenance-free operation
- Adjustment with test gas only required every six to twelve months depending on application
- Large backlit LCD screen
- Two measuring ranges per component
- Automatically corrects fluctuations in barometric pressure
- Monitors the sample gas flow rate
- Two programmable limits
- Three binary inputs
- Eight relay outputs
- Up to four analogue outputs 4-20 mA, electrically isolated
- RS 485