In many applications gas analysis is key for safe and efficient control of process flows, environmental protection, and quality assurance. In extractive gas analysis the location of the gas sampling point is crucial for the reproducibility and accuracy of the analysis results. The specific filter capacity, corrosion resistance and functional equipment requirements for the probe arise from the composition of the sample gas.
Buehler Denox-MB Sample gas probe
- Heated probe with downstream filter inside GfP housing
- The downstream filter can easily be removed by turning the handle 90°
- Adjustable up to 280 °C with Pt100
- For dust loads up to 2 g/m³
- This probe is not suitable for use in Ex areas
- Built-in glass bead receptacle
Category: Sample Gas Probes
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Related products
Buehler GAS 222.10 Sample gas probe
- Unheated probe with outlet filter for indoor installation.
- The filter element can easily be removed by turning the handle 90°.
- For dust loads up to 2g/m³, non-condensable gases.
- The probe has no innate ignition source and is therefore suitable for use in Ex areas.
- Base unit
- Including flange seal and screws
Buehler GAS 222.20 HT Sample gas probe
- Heated probe with downstream filter and weather hood
- The downstream filter can easily be removed by turning the handle 90°
- The probe body and the area around the screw connection for the heated sample gas line are completely isolated
- Electronic temperature controller up to 280 °C with Pt100, high/low temperature alarm and display
- TFor dust loads up to 2 g/m³
- This probe is not suitable for use in Ex areas
Buehler BA 5000 Gas Analyser for IR-Sensitive Gases and Oxygen
- Sturdy 19” sheet steel housing
Option: Desktop version with handles - NAMUR-based operation
- Quick and easy parametrisation and setup
- AUTOCAL with ambient air for virtually maintenance-free operation
- Adjustment with test gas only required every six to twelve months depending on application
- Large backlit LCD screen
- Two measuring ranges per component
- Automatically corrects fluctuations in barometric pressure
- Monitors the sample gas flow rate
- Two programmable limits
- Three binary inputs
- Eight relay outputs
- Up to four analogue outputs 4-20 mA, electrically isolated
- RS 485
Buehler GAS 222.15 MA Sample gas probe
- Heated probe with downstream filter
- The downstream filter can easily be removed by turning the handle 90°.
- Increased degree of protection (IP66) due to the specially developed silicone protective cover
- Particularly suitable for use in high-vibration applications (such as marine) due to special design features
- The probe body and the area around the screw connection for the heated sample gas line are completely insulated
- Self-regulating heater to approx. 180 °C with low temperature alarm.
- For dust loads up to 2 g/m³