- ATEX version
- Suitable for usage in zone 2 and 22 (gases and dusts)
- Auxiliary release on the front
- With door monitoring contact
Euchner STA4A-2131A024MF-EX Electromechanical safety switches according to ATEX directive
SKU:
115585
Category: Safety engineering according to ATEX directive
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
Switching element
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-S-G-SN-C2115Mechanical values and environment
- AC/DC 24 V +10%, -15%
STA4 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
2131 | Slow-action switching contact 2 NC + 1 NO + 1 NC (door monitoring contact) |
Housing material | Die-cast alloy |
Weight | |
Net | 0,6 kg |
Ambient temperature | -20 ... 75 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position NC contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 1 |
Connection | |
3 x | Cable gland M20 x 1.5 |
Clamping range for cable | 6,5 ... 12 mm |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 3000 N |
Locking force FZh | 2300 N |
Retention force | 20 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.24,5 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 50V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
Explosion protection | |
incl. cable gland | II3G Ex nR IIB T4 Gc X /II3D Ex tc IIIC T110°C Dc X |
Monitoring of guard locking and the safety guard position | |
B10D | 11,5 x 106 |
Overtravel | 5 mm |