- ATEX version
- Suitable for usage in zone 2 and 22 (gases and dusts)
- Cable entry M20 x 1.5
- Switching disc made of metal
Euchner SGA1A-2131A-M-EX Electromechanical safety switches according to ATEX directive
SKU:
123460
Category: Safety engineering according to ATEX directive
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Switching element
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-S-G-SN-C2115Mechanical values and environment
2131 | Slow-action switching contact 3 NC + 1 NO |
Housing material | Die-cast alloy, cathodically dipped |
Weight | |
Net | 0,5 kg |
Ambient temperature | -10 ... 75 °C |
Degree of protection | IP67 |
Mechanical life | 2 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 3 |
Number of door position NO contacts | 1 |
Connection | |
3 x | M20 x 1.5 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 6700 1/h |
Retention force | 10 N |
Extraction force | 25 N |
Actuating force | 25 N |
Insertion depth | 24,5 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 50V |
DC-13 | 4A 24V |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Connection cross-section | 0,34 ... 1,5 mm? |
Explosion protection | |
incl. cable gland | II3G Ex nR IIB T5 Gc X / II3D Ex tc IIIC T90° Dc X |
Monitoring of the safety guard position | |
B10D | 3 x 106 |
Overtravel | 5 mm |