- 2 safety contacts, STOP 0; 2 safety contacts, STOP 1
- Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
- Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
Schmersal SRB220XV2/V.2 Safety-monitoring module
SKU:
101195578
Categories: Safe signal processing, Safety-monitoring modules
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Ordering data
Product type description : SRB220XV2 / V.2
Article number (order number) : 101195578
EAN (European Article Number) : 4250116202188
eCl@ss number, Version 9.0 : 27-37-18-19
Replacement article number : 101188429
Certifications
Certificates : cULus , EAC ,
General data
Product name : SRB220XV2 / V.2
Standards : IEC 61508 , IEC/EN 60204-1 , ISO 13849-1 , EN 60947-5-1 ,
Climatic stress : EN 60068-2-78
Enclosure material : Glass-fibre reinforced thermoplastic, ventilated
Material of the contacts, electrical : AgSn0, Ag-Ni, self-cleaning, positive drive
Weight : 475 g
General data - Features
Stop-Category : 0 , 1 ,
Electronic Fuse : Yes
Wire breakage detection : Yes
Short-circuit recognition : Yes
Start input : Yes
Feedback circuit : Yes
Automatic reset function : Yes
Reset edge detection : Yes
Earth connection detection : Yes
Integral System Diagnostics, status : Yes
Number of LEDs : 5
Number of openers : 2
Number of safety contacts : 4
Number of Safety contacts, STOP 0 : 3
Number of Safety contacts, STOP 1 : 2
Safety appraisal
Standards : EN 60947-5-1 , IEC 61508 ,
Safety appraisal - Relay outputs
Performance Level, Stop 0 : e
Performance Level, Stop 1 : d
Category, Stop 0 : 4
Category, Stop 1 : 3
Diagnostic Coverage (DC) Level, Stop 0 : ≥ 99 %
Diagnostic Coverage (DC) Level, Stop 1 : > 60
PFH-Value Stop 0 : 2.00 x 10⁻⁸ /h
PFH-Value Stop 1 : 2.00 x 10⁻⁷ /h
Safety Integrity Level (SIL), Stop 0 : 3
Safety Integrity Level (SIL), Stop 1 : 2
PFD value : 5.30 x 10⁻⁵
PFD value : 5.30 x 10⁻⁵
Product type description : SRB220XV2 / V.2
Article number (order number) : 101195578
EAN (European Article Number) : 4250116202188
eCl@ss number, Version 9.0 : 27-37-18-19
Replacement article number : 101188429
Certifications
Certificates : cULus , EAC ,
General data
Product name : SRB220XV2 / V.2
Standards : IEC 61508 , IEC/EN 60204-1 , ISO 13849-1 , EN 60947-5-1 ,
Climatic stress : EN 60068-2-78
Enclosure material : Glass-fibre reinforced thermoplastic, ventilated
Material of the contacts, electrical : AgSn0, Ag-Ni, self-cleaning, positive drive
Weight : 475 g
General data - Features
Stop-Category : 0 , 1 ,
Electronic Fuse : Yes
Wire breakage detection : Yes
Short-circuit recognition : Yes
Start input : Yes
Feedback circuit : Yes
Automatic reset function : Yes
Reset edge detection : Yes
Earth connection detection : Yes
Integral System Diagnostics, status : Yes
Number of LEDs : 5
Number of openers : 2
Number of safety contacts : 4
Number of Safety contacts, STOP 0 : 3
Number of Safety contacts, STOP 1 : 2
Safety appraisal
Standards : EN 60947-5-1 , IEC 61508 ,
Safety appraisal - Relay outputs
Performance Level, Stop 0 : e
Performance Level, Stop 1 : d
Category, Stop 0 : 4
Category, Stop 1 : 3
Diagnostic Coverage (DC) Level, Stop 0 : ≥ 99 %
Diagnostic Coverage (DC) Level, Stop 1 : > 60
PFH-Value Stop 0 : 2.00 x 10⁻⁸ /h
PFH-Value Stop 1 : 2.00 x 10⁻⁷ /h
Safety Integrity Level (SIL), Stop 0 : 3
Safety Integrity Level (SIL), Stop 1 : 2
PFD value : 5.30 x 10⁻⁵
PFD value : 5.30 x 10⁻⁵