- 1 + 8 Signalling outputs
- Fit for signal evaluation of outputs of safety
magnetic switches - 2 safety contacts, STOP 0;1 safety contact, STOP 1
(adjustable 1 … 30 s) - Multifunctional safety relay module for superior
diagnostics and visualisation - Suitable for signal processing of outputs
connected to potentials (AOPDs), e.g. safety light
grids/curtains - Suitable for signal processing of potential-free
outputs, e.g. emergency stop command devices,
position switches and solenoid interlocks