- 3-stage function
- Dual-channel version
- 22.5 mm installation dimension
- Snap-action switching contact
- With click
- Screw terminals
Euchner ZXE-104833 ZSG, ZSE, ZXE built-in enabling switches
SKU:
104833
Categories: Enabling switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Notes
3-stage function
Enabling function is active only in the second stage (middle position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).
Dimension drawing
2202
Dimension drawing2202
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
- Enabling switch ZXE-104833 for use in housing HBA/HBM
- A click sounds during the change from stage 1 to stage 2 and during the return from stage 2 to stage 1.
2202 | 2NO/NC 1) From position 1 to position 2 –> NO contact; from position 2 to position 3 –> NC contact. |
Rated actuating force according to EN 60947-5-8 | max.100 N |
Material | |
Protective cap | CR |
Housing material | Polyamide |
Weight | |
Net | 0,03 kg |
Ambient temperature | -5 ... 60 °C |
Degree of protection | |
On the front | IP65 |
Connections | IP00 |
Mechanical life | |
Position 1-2-1 | min.0,1 x 106 cycles |
Position 1-2-3-1 | min.0,1 x 106 cycles |
Installation orientation | Any |
Tightening torque | |
Screws | max.0,15 Nm |
Number of switching elements | 2 NO |
Connection | Screw terminal 4-pole |
Stripping length | 5 mm |
Actuating force | max.50 N |
Rated conditional short-circuit current | 100 A |
Utilization category according to EN 60947-5-2 | |
DC-13 | 0.1A 24V |
Fusing | |
external | 0,1 A Medium slow-blow |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Switching current | 5 ... 100 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
single conductor | 0,33 ... 1,5 mm? |
multiple conductor | 0,33 ... 0,75 mm? |
Connection cross-section, AWG | |
multiple conductor | 22 ... 18 AWG |
single conductor | 22 ... 16 AWG |
Breaking capacity | max.0,25 W |
Additional feature | Click |
In compliance with | DIN EN 60947-5-8 |
Color | |
Housing | Black |
Protective cap | Black |
B10D | 0,75 x 106 |