- 3-stage function
- Housing G3
- Straight connection cable, 10 m
- Two illuminated buttons
- Selector switch
- Including holder
Euchner ZSB087821 ZSB with plus/minus pushbuttons
SKU:
87821
Categories: Enabling switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Switching element
CableThe high quality connection cables (individual screening of the safety contacts) are available straight.
Selector switch (12-stage)For the selection of different axes or ranges. All outputs are open between the switch positions on the selector switch (break-before-make switching)!
3-stage functionEnabling function is active only in the second stage (middle position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).
Illuminated + and - buttonsThese buttons can be cond individually. For example, for moving axes in positive or negative direction.
Dimension drawing
Dimension drawing
2220 with selector switch
Dimension drawingDimension drawing2220 with selector switch
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
2220 | 2/NC |
Material | |
Housing | Plastic yellow |
Cap | Elastomer PAK arm, black |
Weight | |
Net | 2,5 kg |
Ambient temperature | -5 ... 50 °C |
Degree of protection | IP65 |
Mechanical life | |
Position 1-2-1 | min.0,1 x 106 |
Position 1-2-3-1 | min.0,1 x 106 |
Switching principle | Slow-action contact element |
Number of positively driven contacts | 2 |
Number of NO contacts | 2 |
Connection | Flying lead |
Cable length | |
straight | 10 m |
Rated conditional short-circuit current | 100 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 2A 24V |
400mA 24V | |
DC-13 | 2A 24V |
100mA 24V | |
Short circuit protection according to IEC 60269-1 | |
at 24V | 2A gG |
Additional elements at 24V | 0.1A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 0,8 kV |
Switching voltage | |
Min. at 10mA | min.12 V |
Switching current | |
Min. at 24 V | min.1 mA |
Degree of contamination (external, according to EN 60947-1) | |
Industry | 3 |
Connecting cable | 8x0.5mm? + 8x0.14mm? |
Additional feature | |
Version | 2 pushbuttons illuminated (+ and -) 1 selector switch |
Enabling switch | |
B10D | 0,5 x 106 |