- Housing G1
- 3-stage function
- Positively driven contacts
- Dual-channel version
Euchner ZSA2B2CAS1 Enabling switches with AS – Interface
SKU:
91580
Categories: Safety engineering with AS - Interface, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
AS-Interface inputs
3-stage function
Enabling function is active only in the second stage (middle position, actuating point). Enabling is canceled when the button is released or pushed all the way down (panic function).
Dimension drawing
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
D0, D1 | NO contact |
D2, D3 | NO contact |
Material | Plastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -5 ... 50 °C |
Degree of protection | IP65 mating connector inserted and screwed tight |
Mechanical life | |
Position 1-2-1 | 0,1 x 106 |
Position 1-2-3-1 | 0,1 x 106 |
Switching principle | Slow-action contact element |
Number of NO contacts | 2 |
Connection | M12 plug connector, 4-pin |
ASi voltage | 30 V 22,5 ... 31,6 V |
ASi operating current | max.45 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switching characteristics | 3-stage enabling switch |
ASi slave type | |
According to ASI specification 3.0 | EA code: 7 |
ID code: B | |
ASi data in | |
According to ASI safety at work | D0, D1, D2, D3 |
In compliance with | 60947-5-8 |
Enabling switch | |
B10D | 0,5 x 106 |