- Mounting on plastic housing TP with actuating head and guard locking pin made of metal
- High locking forces of 5000 N
- Auxiliary release on the switch head
- Actuating element for contact separation on the front
- Plug connector M12
Euchner TK1-528CB024SM8 TK very high locking force
SKU:
122828
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Solenoid operating voltage
Switching element
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool.
Contact separationWhen actuated, positively driven NC contacts 21-22 are opened. Guard locking is not fully unlocked. The auxiliary release must be sealed to prevent tampering (e.g. with sealing lacquer).
Electrical connection ratings
Reliability values according to EN ISO 13849-1
- AC/DC 24 V +10%, -15%
TK1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
528 | Slow-action switching contact 1 NC + 1 NO |
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,6 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 1 |
Number of NO contacts | 1 |
Connection | |
1 x | Plug connector M12 |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 5000 N |
Thermal rated current Ith | 1 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 1A 24V |
DC-13 | 1A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 1A gG |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Monitoring of guard locking | |
B10D | 2 x 106 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |