- Escape release on the rear
- With door monitoring contact
Euchner STP4A-4121A024MC1993 STP plastic switch with metal head
SKU:
100322
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
Switching element
Escape release (C1993, long actuator shaft)This is used for manual release of guard locking from within the danger area without tools. With identification of On/Off position.
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
- AC/DC 24 V +10%, -15%
STP4 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
4121 | Slow-action switching contact 2 NC + 1 NC / 1 NO (door monitoring contact) |
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position NC contacts | 1 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Connection | |
3 x | M20 x 1.5 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 2500 N |
Locking force FZh | 2000 N |
Retention force | 20 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.24,5 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 50V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
C number | |
C1993 | Escape release long |
Monitoring of guard locking and the safety guard position | |
B10D | 5 x 106 |
Overtravel | 5 mm |