Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
Switching element
Combination available:
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Electrical connection ratings
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
- AC/DC 24 V +10%, -15%
STM2 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
UK | For monitoring the guard locking (built-in solenoid) slow-action switching contact 1 NC |
SK | For monitoring the door/actuator position |
242 | Slow-action switching contact 1 NC + 1 NO |
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,4 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 2 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 1 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 1 |
Connection | |
1 x | M20 x 1.5 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 1000 N |
Locking force FZh | 700 N |
Retention force | 20 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.24,5 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 6 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
Monitoring of guard locking and the safety guard position | |
B10D | 2 x 106 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Overtravel | 5 mm |