- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 pushbuttons illuminated with symbol
- Push-pull plug
- Including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Multicode
Euchner MGB-L2HB-PNC-L-117027 MGB-PN
SKU:
117027
Categories: Multifunctional Gate Boxes, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Flexible usage as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring).
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.
Dimension drawing
MGB: The MGB-System in use
MGB: MGB Impact test
MGB: Mounting left door, with escape release
Mounting left door, without escape release
Mounting right door, without escape release
MGB: Deactivating guard lock monitor
MGB: Activating guard lock monitor
MGB: Activating release monitoring
MGB: Change color-lens push button
Dimension drawing
Technical data
Locking module MGB-L2B-PNC-L-117026 (Order no. 117026)
Mechanical values and environment
Electrical connection ratings
Work area
Interface, bus
Other
Reliability values according to EN ISO 13849-1
Handle module MGB-H-AA1A6-L-111839 (Order no. 111839)
Mechanical values and environment
Other
Components
117026
Locking module MGB-L2B-PNC-L-117026
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Reaction time | |
Bolt position | max.550 ms Switch-off time |
Door position | max.550 ms Switch-off time |
Enabling switch | max.250 ms Switch-off time |
Guard locking | max.550 ms Switch-off time |
Emergency stop / machine stop | max.250 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | Push-pull power |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
Plug connector RC12 | |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Transponder coding | Multicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Fusing | |
external | min.1 A Slow blow |
Assured switch-off distance Sar | max.65 mm |
Data interface | |
Data protocol | |
Bus protocol | Profinet (IEC 61158 type 10) |
Safety protocol | Profisafe (IEC 61784-3-3) |
Product version number | V3.30.11 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 |
Diagnostic Coverage (DC) | 99 |
Emergency stop | |
B10D | |
Emergency stop | 0.1 x 106 |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Enabling switch | |
B10D | |
Enabling switch | According to manufacturer’s specifications |
Enabling switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Additional feature | With mounting plate and automatic lockout mechanism |
Product version number | V3.0.0 |
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 pushbuttons illuminated with symbol
- Push-pull plug
- Including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Multicode
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate