- Guard locking with guard locking monitoring
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- One illuminated pushbutton
- With plug connector RC26
- With plug connector M12 for enabling switch
- With escape release
- Unicode
Euchner MGB-L1HE-ARA-L-157890 MGB-AR
SKU:
157890
Categories: Multifunctional Gate Boxes, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Guard locking type
Door stopA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicatorThe LED indicator indicates all important system and status information.
Monitoring outputs
Emergency stop device
Pushbutton
Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone.
Connection for enabling switchThe device has an M12 plug connector for the direct connection of an enabling switch (e.g. ZSA, order no.: 110560).
Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
Plug connector RC26
MGB: The MGB-System in use
MGB: MGB Impact test
MGB: Mounting left door, with escape release
Mounting left door, without escape release
Mounting right door, without escape release
MGB: Changing single wiring (AP) to series wiring (AR)
MGB: Deactivating guard lock monitor
MGB: Activating guard lock monitor
MGB: Activating release monitoring
MGB: Change color-lens push button
Dimension drawingDimension drawingDimension drawingDimension drawingPlug connector RC26
Technical data
Locking module MGB-L1-ARA-AL3A1-S8-L-157887 (Order no. 157887)
Mechanical values and environment
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
Escape release MGB-E-A-100465 (Order no. 100465)
Mechanical values and environment
Other
Handle module MGB-H-AA1A3-L-111158 (Order no. 111158)
Mechanical values and environment
Other
Components
157887
Locking module MGB-L1-ARA-AL3A1-S8-L-157887
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted into the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics; there is a fault |
S1 | Two positively driven contacts and one NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
S2 | One NO contact, illuminated |
Housing material | Reinforced plastic; die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | |
Plug connector RC26 | |
Plug connector SFF5 | |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |
Housing material | Die-cast zinc/stainless steel powder-coated |
Weight | |
Net | 0,75 kg |
Ambient temperature | -20 ... 55 °C |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Product version number | V2.0.0 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Additional feature | With automatic lockout mechanism |
Product version number | V3.0.0 |
- Guard locking with guard locking monitoring
- Emergency stop according to ISO 13850
- One pushbutton (illuminated, wh)
- With plug connector RC26
- With plug connector M12 for enabling switch
- Unicode
- Escape release from the danger zone
- Door handle signal red
- Extended actuation axis for thicker doors (available optionally)
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle