Specification
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Dimension drawing
Dimension drawing
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Work area
Interface, bus
Controls and indicators
Other
Reliability values according to EN ISO 13849-1
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP42 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Reaction time | |
Door position | max.550 ms Switch-off time |
Bolt position | max.550 ms Switch-off time |
Operating mode selector switch | max.220 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | |
7/8" Power | |
7/8" Power | |
Acc. to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12 D-coded, screened |
M12 D-coded, screened |
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Transponder coding | Unicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Fusing | |
external | min.1 A Slow blow |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Assured switch-off distance Sar | max.65 mm |
Data interface | |
Data protocol | |
Safety protocol | Profisafe (IEC 61784-3-3) |
Bus protocol | Profinet (IEC 61158 type 10) |
Belegungsschema | L1 |
Belegungsschema | B4 |
Position 1 | |
Ausfuhrung | Key-operated switch |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 1NO |
Position 90 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | Printed |
Farbe | white |
Schaltelement | 1NO |
Position 91 | |
Ausfuhrung | Operating mode selector switch |
Einlegeschild | O ; I |
Extras | |
Farbe | |
Schaltelement | Code 2 of 3 |
Position 92 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | Printed |
Farbe | white |
Schaltelement | 1NO |
Product version number | V3.30.10 |
Monitoring of the position of the safety guard | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 |
Diagnostic Coverage (DC) | 99 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Selector switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Mission time | 20 |