- Locking (without guard locking)
- Can be connected in series with other AR devices (CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated, ye, wh)
- With cable entry
- Unicode
Euchner MGB-L0-ARA-AB8A1-M-106106 MGB-AR
SKU:
106106
Categories: Multifunctional Gate Boxes, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Guard locking type
Door hingeA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicatorThe LED indicator indicates all important system and status information.
Monitoring outputs
Emergency stop device
Pushbutton
Dimension drawing
Cable entry
MGB: The MGB-System in use
MGB: MGB Impact test
MGB: Mounting left door, with escape release
Mounting left door, without escape release
Mounting right door, without escape release
MGB: Changing single wiring (AP) to series wiring (AR)
MGB: Deactivating guard lock monitor
MGB: Activating guard lock monitor
MGB: Activating release monitoring
MGB: Change color-lens push button
Dimension drawingCable entry
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Controls and indicators
Other
Reliability values according to EN ISO 13849-1
MGB-L0... | The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position. |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics; there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, yellow, illuminated |
S3 | 1 NO contact, white, illuminated |
Housing material | Reinforced plastic; die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.10 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | With auxiliary contact |
Farbe | |
Schaltelement | 2 pos. driven NC + 1NO |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | Yellow |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Monitoring of the position of the safety guard | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |