- For connecting MGB2 or MCM modules
- Interface to PROFINET/PROFIsafe
- Connection via plug connector RJ45, AIDA compliant
- Remote or direct mounting
- Integrated switch
- Compatible with all Modular devices
Euchner MBM-PN-S3-MLI-3B-156310 Bus modules MBM-PN
SKU:
156310
Category: Multifunctional Gate Boxes
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
PROFINET interface
Plug connector RJ45 AIDA-compliant (push-pull plug according to IEC 61076-3-117, variant 14)
PROFINET switch
Linear topology network structure due to integrated switch (supports MRP).
MLI connections (module plug connector)
An MGB2 Modular or an MCM Modular can be connected directly to a bus module (direct plug). Alternatively, the modules can be connected using commercially available connecting cables M12, 5-core (cable connect).
Dimension drawing
Dimension drawing
MGB2 Modular: an overview
Dimension drawingDimension drawing
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Interface, bus
Reliability values according to EN ISO 13849-1
Housing material | Fiber glass reinforced plastic, die-cast zinc, nickel plated |
Weight | |
Net | 0,8 kg |
Ambient temperature | |
At UB = 24V DC | -25 ... 55 °C |
Degree of protection | IP65 |
Resilience to vibration | In acc. with EN 60947-5-3 |
Installation orientation | Any |
Connection | Push-pull power |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
Push-pull RJ45 | |
Push-pull power | |
ML1C / ML2C | |
Type specification | M12 EN 61076-2-101 / A-coded |
Insertion cycles | 100 |
Connection | Screw terminal |
Connection type | Plug |
Number of pins | 5 |
ML1D | |
Insertion cycles | 100 |
Connection | Connector (unlocked) |
Connection type | Plug |
Number of pins | 5 |
Current consumption | max.150 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Maximum feed-in current in the connection block | |
XD1, XD2 | max.16000 mA |
EMC protection requirements | EMC directive 2014/30/EU |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
MLI | 5-pin, M12x1 |
Safety class | III |
Data interface | |
Data protocol | |
Safety protocol | Profisafe (IEC 61784-3-3) |
Bus protocol | Profinet (IEC 61158 type 10) |
Performance Level | PL e |
PFHD | 1.14 x 108 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |