- Light curtain master
- For cascading (series connection)
- Resolution 30 mm
- Protective field height 910 mm
- Range 12 m
- With plug connector M12
- Two safety outputs (OSSD)
- Installation material is included with the product
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Protective function
hand protection
Cascading (series connection)
Following combinations are possible:
LED function display
Transmitter
Receiver
Pin assignment transmitter
Connector assignment receiver
Electrical connection ratings
Reliability values according to EN ISO 13849-1
Variante A: | Master-slave 2-slave 1 |
Variante B: | Master-slave 1 |
LED OK | Normal operation |
LED ERROR | Faults |
LED STOP | Stop |
LED TEST | Test function |
LED START | Start/ restart |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | 24 V DCB | Operating voltage, 24 V DC | BN | |
2 | RANGE 0 | Device configuration, corresponds to the standard EN 61131-2 | WH | |
3 | 0 V DC | Operating voltage, 0 V DC | BU | |
4 | RANGE 1 | Device configuration, corresponds to the standard EN 61131-2 | BK | |
5 | FE | Function earth (must be connected to meet the EMC requirements) | GY |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | FO1AB | Safety output, channel 1 | WH | |
2 | 24 V DC | Operating voltage, 24 V DC | BN | |
3 | FO1B | Safety output, channel 2 | GN | |
4 | K1_K2/RESTART | Feedback external contactors | YE | |
5 | SEL_A | Device configuration | GY | |
6 | SEL_B | Device configuration | PK | |
7 | 0 V DC | Operating voltage, 0 V DC | BU | |
8 | FE | Function earth (must be connected to meet the EMC requirements) | RD |
Number of safety outputs | 2 Static, self-monitoring PNP safety outputs |
Resolution | 30 mm |
Height of the protective field | 910 mm |
Height of the sensor | 986 mm |
Maximum length of connecting cables | 100 m |
Range of the protective field | 12000 mm |
Dimensions | 28x30 mm |
Ambient temperature | -30 ... 55 °C |
Degree of protection | IP 65 / IP 67 |
Installation orientation | Any |
Connection | Plug connector M12 (5-pin transmitter / 8-pin receiver) |
Cascadable | Yes |
Muting possible | In combination with external sensors and an evaluation unit |
Operating voltage DC | 24 V DC -20% ... +20% |
Current consumption | 400 mA |
Power consumption | |
Transmitter | 1 W |
Receiver | 2 W |
LED indicator | Yes |
ESPE type | 4 |
Performance Level | PL e |
PFHD | 1,43x10-8 |
Safety Integrity Level | SIL 3 / SILCL 3 |
Mission time | 20 y |