- Resolution 40 mm
- Protective field height 1,810 mm
- Range 12 m
- With plug connector M12
- Two safety outputs (OSSD)
- Installation material is included with the product
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Protective function
hand protection
LED function display
Transmitter
Receiver
Pin assignment transmitter
Connector assignment receiver
Electrical connection ratings
Reliability values according to EN ISO 13849-1
LED OK | Normal operation |
LED ERROR | Fault state |
LED STOP | Stop state |
LED TEST | Test function |
LED START | Start/ restart |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | 24 V DCB | Operating voltage, 24 V DC | BN | |
2 | RANGE 0 | Device configuration, corresponds to the standard EN 61131-2 | WH | |
3 | 0 V DC | Operating voltage, 0 V DC | BU | |
4 | RANGE 1 | Device configuration, corresponds to the standard EN 61131-2 | BK | |
5 | FE | Function earth (must be connected to meet the EMC requirements) | GY |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | FO1AB | Safety output, channel 1 | WH | |
2 | 24 V DC | Operating voltage, 24 V DC | BN | |
3 | FO1B | Safety output, channel 2 | GN | |
4 | K1_K2/RESTART | Feedback external contactors | YE | |
5 | SEL_A | Device configuration | GY | |
6 | SEL_B | Device configuration | PK | |
7 | 0 V DC | Operating voltage, 0 V DC | BU | |
8 | FE | Function earth (must be connected to meet the EMC requirements) | RD |
Number of safety outputs | 2 Static, self-monitoring PNP safety outputs |
Resolution | 40 mm |
Height of the protective field | 1810 mm |
Height of the sensor | 1863 mm |
Maximum length of connecting cables | 100 m |
Range of the protective field | 12000 mm |
Dimensions | 28x30 mm |
Ambient temperature | -30 ... 55 °C |
Degree of protection | IP 65 / IP 67 |
Installation orientation | Any |
Reaction time | 16 ms |
Connection | Plug connector M12 (5-pin transmitter / 8-pin receiver) |
Cascadable | No |
Muting possible | In combination with external sensors and an evaluation unit |
Operating voltage DC | 24 V DC -20% ... +20% |
Current consumption | 400 mA |
Power consumption | |
Transmitter | 1 W |
Receiver | 2 W |
LED indicator | Yes |
ESPE type | 2 |
Performance Level | PL c |
PFHD | 6,88x10-8 |
Safety Integrity Level | SIL 1 / SILCL 1 |
Mission time | 20 y |