- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With two plug connectors M12
- Multicode
- Door monitoring output
- With escape release
- Approach directions A, B and C (delivery state)
Euchner CTP-L1-AR-M-HA-AE-SAB-123308 CTP-AR safety switch with guard locking
SKU:
123308
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Multicode evaluation
Every suitable actuator is detected by the switch.
Guard locking type
Escape release
This is used for manual release of guard locking from the danger zone without tools.
Connector assignment
Electrical connection ratings
Work area
Other
Reliability values according to EN ISO 13849-1
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | FI1B | Enable input for channel 2 | WH | |
X 1.2 | UB | Operating voltage of AR electronics 24 V DC | BN | |
X 1.3 | FO1A | Safety output, channel 1 | GN | |
X 1.4 | FO1B | Safety output, channel 2 | YE | |
X 1.5 | OL | Guard locking monitoring output | GY | |
X 1.6 | FI1A | Enable input for channel 1 | PK | |
X 1.7 | 0 V UB | Operating voltage of AR electronics 0 V | BU | |
X 1.8 | RST | Reset input | RD | |
X 2.1 | IMM | Operating voltage of guard locking solenoid 0 V | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | OI | Diagnostic output | BU | |
X 2.4 | IMP | Operating voltage of guard locking solenoid 24 V DC | BK | |
X 2.5 | - | n.c. | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | 8 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.140 ms |
Test pulses | max.1,0 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |