- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switch with guard locking and integrated evaluation electronics
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Diagnostics output OI
- Approach directions A, B and C (delivery state)
Euchner CTP-L1-AP-U-HA-AZ-SA-EX-129512 Transponder-coded safety switches according to ATEX directive
SKU:
129512
Category: Safety engineering according to ATEX directive
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Guard locking type
Connector assignment
Electrical connection ratings
Work area
Other
Reliability values according to EN ISO 13849-1
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | PIN | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
8 | IMM | Operating voltage of guard locking solenoid 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,78 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Explosion protection | |
incl. cover | II3G Ex nA IIB T4 Gc X / II3D Ex tc IIIC T110°C Dc X |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |