- Safety switch with integrated evaluation electronics
- Safety switch CES-C04 encapsulated in epoxy resin
- Tested for material resistance in accordance with Ecolab specifications
- Two safety outputs (semiconductor outputs)
- Category 4/PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 20 m, with cable end sleeves
- Multicode
- Monitoring output OD
Euchner CES-I-AP-M-C14-U20-158631 CES-AP safety switch
SKU:
158631
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Installation position
Permissible installation position
Attention:The operating distance may vary depending on the background material and installation situation.
(Only in combination with actuator CES-A-BBN)
Typical operating distance
For a side approach direction for the actuator and safety switch, a minimum distance of s = 10 mm must be maintained so that the operating distance of the side lobes is not entered.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
Terminal assignment
Electrical connection ratings
Work area
Reliability values according to EN ISO 13849-1
In combination with Actuator CES-A-BBN-C14-160441Operating distance
- Category 4/PL e according to EN 13849-1
STATE | Status LED |
DIA | Diagnostic LED |
Designation | Function | Conductor coloring of connecting cable |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OD | Monitoring output | GY |
Housing material | Two-component epoxy resin |
Weight | |
Net | 0,7 kg |
Ambient temperature | |
At UB = DC 24 V | 0 ... +50 °C |
Cable static | -40 ... 80 °C |
Cable dynamic | -25 ... 80 °C |
Degree of protection | IP65 / IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.150 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | 2 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 20m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | max.260 ms |
Monitoring output OD | |
Type of output | Monitoring, semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U (FO1A1) / U (FO1B) | UB-1,5V ... UB V DC |
LOW U (FO1A1) / U (FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24 V 150 mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Switch-on distance | |
Installation position A / in z direction | max.24 mm ALU |
max.22 mm PVC | |
Installation position D / in z direction | max.23 mm ALU |
max.18 mm PVC | |
Assured switch-off distance Sar | |
Installation position D / in x/z direction | max.58 mm |
Installation position A / in y direction | max.72 mm |
Installation position A / in x/z direction | max.64 mm |
Installation position D / in y direction | max.68 mm |
Assured operating distance Sao | |
Installation position A / in z direction | max.11 mm PVC |
max.10 mm ALU | |
Installation position D / in z direction | max.6 mm ALU |
max.5 mm PVC |