- Four read heads can be connected
- 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
- Start button and feedback loop can be connected
- Multicode
- Plug-in connection terminals
- Category 4/PL e according to EN ISO 13849-1
Euchner CES-AZ-UES-04B Evaluation units CES-AZ
SKU:
105141
Categories: Sensors, Transponder-coded read heads with external evaluation
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Multicode evaluationEvery suitable actuator is detected by the evaluation unit.
Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories
Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
Additional connections
Important: The plug-in connection terminals are not included and must be ordered separately.
Dimension drawing
Wiring diagram
Dimension drawingWiring diagram
Technical dataApprovals
Mechanical values and environment
- Category 4/PL e according to EN ISO 13849-1
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Safety output status |
TST | Input for self-test |
O1 ... O4 | Monitoring outputs (semiconductor) |
DIA | Diagnostics output |
Y1, Y2 | Feedback loop |
S | Start button connection (monitoring of the falling edge) |
Housing material | Plastic PA6.6 |
Weight | |
Net | 0,25 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Atmospheric humidity | |
Not condensing | max.80 % rH |
Degree of protection | IP20 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Mounting distance | |
Sideways toward the neighboring device | min.10 mm |
Number of read heads | Max. 4 read heads can be connected |
Ready delay | 10 ... 12 s |
Reaction time | |
After change in the actuation status, 2 active actuators | max.290 ms |