- Two read heads can be connected
- 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
- Start button and feedback loop can be connected
- Unicode
- Plug-in connection terminals
- Category 4/PL e according to EN ISO 13849-1
Euchner CES-AZ-AES-02B Evaluation units CES-AZ
SKU:
104775
Categories: Sensors, Transponder-coded read heads with external evaluation
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in.
Only the last actuator taught in is detected.
New actuators are taught-in by fitting a jumper.
Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories
Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
Additional connections
Important: The plug-in connection terminals are not included and must be ordered separately.
- Category 4/PL e according to EN ISO 13849-1
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Safety output status |
TST | Input for self-test |
O1, O2 | Monitoring outputs (semiconductor) |
DIA | Diagnostics output |
Y1, Y2 | Feedback loop |
J1, J2 | Teach-in input |
S | Start button connection (monitoring of the falling edge) |
Housing material | Plastic PA6.6 |
Weight | |
Net | 0,25 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Atmospheric humidity | |
Not condensing | max.80 % rH |
Degree of protection | IP20 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Mounting distance | |
Sideways toward the neighboring device | min.10 mm |
Number of read heads | Max. 2 read heads can be connected |
Ready delay | 10 ... 12 s |
Reaction time | |
After change in the actuation status, 1 active actuator | max.210 ms |