Brand |
---|
Comitronic-Bti CO13XXL CO13XXL – Management and control of emergency stops
Control of emergency stops
SKU:
CO13XXL
Category: Safety Modules
Additional information
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Safety management in a compact 22.5 mm format
Mono or two-channel with wiring. "Low consumption" Inputs
Removable terminals
Performance level with AWAX controller: PL = d
Safety category: 3 (two-channel)
Safety Integrity Level: SIL 2
Time before dangerous failure: MTTFd = 240 years
Cycle before dangerous failure: B10d=100,000 at 5A
Risk duration: 20 ms max.
Cable severing protection: yes (opening of safety lines)
Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA
Indicators: 3 LEDs for diagnostics
Reset: configurable by dip-switch (SR=Automatic, N=manual)
Mounting: symmetrical DIN 35mm rail on DIN 50022
Mounting: IP 20 electrical box
Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
Temperature: -20°C to +60°C
Related products
Comitronic-Bti AWAX26XXLT6 AWAX 26XXL – Safety Relays – Self Check Box
Sensor controller on Acotom process / mechanical switches / emergency stops
Output contacts 8A/250V
Anti-gluing control of the reset button
Ultra-fast "DLC" short-circuit check : Short-circuit detection in 2 µs, self-resetting
Safety management in a compact 22.5 mm format
12V version for embedded applications
Performance level with AWAX controller: PL = e
Safety category: 4
Safety Integrity Level: SIL 3