In many applications gas analysis is key for safe and efficient control of process flows, environmental protection, and quality assurance. In extractive gas analysis the location of the gas sampling point is crucial for the reproducibility and accuracy of the analysis results. The specific filter capacity, corrosion resistance and functional equipment requirements for the probe arise from the composition of the sample gas.
Buehler Denox-MB Sample gas probe
- Heated probe with downstream filter inside GfP housing
- The downstream filter can easily be removed by turning the handle 90°
- Adjustable up to 280 °C with Pt100
- For dust loads up to 2 g/m³
- This probe is not suitable for use in Ex areas
- Built-in glass bead receptacle
Category: Sample Gas Probes
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Related products
Buehler GAS 222.11 Sample gas probe
- Unheated
- Base unit with manual shut-off valve
- For in-situ and outlet filter
- With blowback connection
- The outlet filter can easily be removed by turning the handle 90°.
- For dust loads up to 2g/m³, non-condensable gases. Combined with inlet filter up to 10g/m³ and higher
- Including flange seal and screws
The probe has no innate ignition source and is therefore suitable for use in Ex areas.
Buehler GAS 222.10 Sample gas probe
- Unheated probe with outlet filter for indoor installation.
- The filter element can easily be removed by turning the handle 90°.
- For dust loads up to 2g/m³, non-condensable gases.
- The probe has no innate ignition source and is therefore suitable for use in Ex areas.
- Base unit
- Including flange seal and screws
Buehler BA 2000 Oxygen Flue Gas Analyser
- Fast response time
- Tool-less filter change
- Easy handling
- Flue gas temperatures up to 1600 °C / 2912 °F
- Durable ZrO2measuring cell
- Display with O2measurements
- 4-20 mA output signal
- Ambient temperature -20 to +70 °C respectively 4 to 158 °F
- No reference glass required
- No test gas required
- No gas conditioning required
- Calibration with instrument air
Buehler GAS 222.20 HT Sample gas probe
- Heated probe with downstream filter and weather hood
- The downstream filter can easily be removed by turning the handle 90°
- The probe body and the area around the screw connection for the heated sample gas line are completely isolated
- Electronic temperature controller up to 280 °C with Pt100, high/low temperature alarm and display
- TFor dust loads up to 2 g/m³
- This probe is not suitable for use in Ex areas