Features
- Output ratings up to 95 Amps at 600VAC
- Built-in overvoltage protection
- DBC substrate for superior thermal performance
- LED input status indicator
- IP20 touch-safe housing
- AC or DC control
- 4000 VAC optical isolation
- C-UL-US and TUV approved
Brand |
---|
Description | 25 A | 50 A | 95 A |
Operating Voltage (47-440Hz) [Vrms] | 48-600 | 48-600 | 48-600 |
Transient Overvoltage [Vpk] | 1200 | 1200 | 1200 |
Maximum Off-State Leakage Current @ Rated Voltage [mArms] | 1 | 1 | 1 |
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] | 500 | 500 | 500 |
Load Current, General Use UL508/LC A IEC 62314 @ 40°C [Arms] | 25 | 50 | 95 |
Load Current, Motor Starting UL508 FLA/LC B IEC 62314 @ 40°C [Arms] | 8.5/4.8 | 14/7.6 | 26/14 |
Minimum Load Current [Arms] | 100 | 100 | 150 |
Maximum 1 Cycle Surge Current (50/60Hz) [Apk] | 286/300 | 716/750 | 1290/1350 |
Maximum On-State Voltage Drop @ Rated Current [Vpk] | 1.35 | 1.35 | 1.30 |
Thermal Resistance Juntion to Case (Rjc) [°C/W] | 0.49 | 0.27 | 0.2 |
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] | 409/375 | 2563/2343 | 8320/7593 |
Minimum Heat Sink for Rated Current @ 40ºC [°C/W] | 2 | 0.7 | 0.25 |
Minimum Power Factor (at Maximum Load) | 0.5 | 0.5 | 0.5 |
Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC | 0.5 (0.37) | 1 (0.74) | 2 (1.5) |
Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC | 1.5 (1.1) | 3 (2.2) | 5 (3.73) |
Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC | 3 (2.24) | 5 (3.7) | 10 (7.4) |