Catalog
Comitronic-Bti AMX5/12M AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/3M AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/6M AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/MKT AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/OX/12M AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/OX/3M AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/OX/6M AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMX5/OX/MKT AMX – Safety Switch stand alone
Controls the position of hazardous machine doors/cases with integrated self-checking
Contactless coded sensor with electronic technology and relays
IP68 PA6 / IP69K INOX316L
Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1
Performance level and category with AWAX controller: Cat 4 up to PL=e
Integrated safety level: SIL 2 according to IEC 61508
Comitronic-Bti AMXR-S/12M AMXR-S – Safety Switch stand alone with RFID coding
Controls the position of safety doors/casings with RFID encoding
RFID sensor with 16 million codes
Category 3 total security management without an external controller
Programmable code through auto-learning (no software or PC)
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3 (EN 954-1)
Cycle after dangerous failure: B10d = 2000000 at 2 Amps
Comitronic-Bti AMXR-S/3M AMXR-S – Safety Switch stand alone with RFID coding
Controls the position of safety doors/casings with RFID encoding
RFID sensor with 16 million codes
Category 3 total security management without an external controller
Programmable code through auto-learning (no software or PC)
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3 (EN 954-1)
Cycle after dangerous failure: B10d = 2000000 at 2 Amps
Comitronic-Bti AMXR-S/6M AMXR-S – Safety Switch stand alone with RFID coding
Controls the position of safety doors/casings with RFID encoding
RFID sensor with 16 million codes
Category 3 total security management without an external controller
Programmable code through auto-learning (no software or PC)
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3 (EN 954-1)
Cycle after dangerous failure: B10d = 2000000 at 2 Amps