Brand |
---|
Baumer OM70-L0140.HH0100.EK Distance sensor
- Adjustable reference distance (zero point position)
- Intuitive limitation of the measuring range
- Configurable switching output
- Selectable filters and trigger modes
- Additional data such as signal quality on request
- Export and import function for parameter sets
SKU:
11220166
Categories: Laser Sensors, Sensors
Additional information
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Technical data
general data
- type
- distance measuring
- version
- OM70 laser line
- measuring distance Sd
- 40 … 140 mm
- measuring range Mr
- 100 mm
- sweet spot
- 100 mm
- adjustment
- Webserver, Ethernet TCP/IP
- power on indication
- LED green
- output indicator
- LED yellow / LED red
- ethernet link indication
- LED blue
- resolution
- 1,2 … 2,5 µm
- repeat accuracy
- 0,3 … 0,7 µm
- linearity error
- ± 0,07 % Mr
- light source
- pulsed red laser diode
- wave length
- 660 nm
- laser class
- 1
- beam type
- line
- temperature drift
- 0,015 % So/K
- hysteresis digital output
- adjustable
- response delay
- 0,8 ms
- measuring frequency
- 2000 Hz
- voltage supply range +Vs
- 15 … 28 VDC
- current consumption max. (no load)
- 75 mA
- output circuit
- analog and digital
- output signal
- 4 ... 20 mA / 2 ... 10 mA / 0 ... 10 VDC / 0 ... 5 VDC
- output current
- < 100 mA
- switching output
- push-pull
- short circuit protection
- yes
- reverse polarity protection
- yes, Vs to GND
- interface
- Ethernet TCP/IP
- protocol
- Profinet, Modbus TCP, OPC UA, UDP streaming
- webserver
- yes
- width / diameter
- 26 mm
- height / length
- 74 mm
- depth
- 55 mm
- type
- rectangular, front view
- housing material
- aluminum
- front (optics)
- glass
- connection types
- connector M12 8 pin & M12 4 pin
- weight
- 135 g
- ambient light immunity
- < 35 kLux
- operating temperature
- -10 … +50 °C
- protection class
- IP 67
- storage temperature
- -20 … +60 °C
- vibration (sinusoidal)
- IEC 60068-2-6:2008
- 1 mm p-p at f = 10 - 55 Hz, duration 5 min per axis
- 30 min endurance at f = 55 Hz per axis
- shock (semi-sinusoidal)
- IEC 60068-2-27:2009
- 30 g / 11 ms, 6 jolts per axis and direction