- Auxiliary release on the front
- Escape release from the rear
- With door monitoring contact
Euchner STA3A-2131A024MC1993 STA metal switch with metal head
SKU:
103660
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
Switching element
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Escape releaseThis is used for manual release of guard locking from within the danger area without tools. With identification of On/Off position.
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
- AC/DC 24 V +10%, -15%
STA3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
2131 | Slow-action switching contact 2 NC + 1 NO + 1 NC (door monitoring contact) |
Housing material | Alloy - die-cast |
Weight | |
Net | 0,6 kg |
Ambient temperature | -20 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position NC contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 1 |
Connection | |
3 x | M20 x 1.5 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3000 N |
Locking force FZh | 2300 N |
Retention force | 20 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.24,5 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 50V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
C number | |
C1993 | Escape release long |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 11,5 x 106 |
Overtravel | 5 mm |