- Guard locking for protection of persons or processes
- Locking module MGB2 for connection to a bus module MBM
- Locking with monitored guard locking
- Category 4/PL e for the evaluation of all safety functions
- Open version (without blanking covers)
- Adjustable door hinge
- Unicode
- Compatible with all Modular devices
Euchner MGB2-L1-MLI-U-Y0000-BJ-136776 Locking modules MGB2-L.-MLI
SKU:
136776
Category: Multifunctional Gate Boxes
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Guard locking type
Door hinge
On the locking modules, the door hinge can be changed from right to left and vice versa at any time with little effort.
Dimension drawing
Dimension drawing
MGB2 Modular: an overview
Multifunctional door locking systems
Dimension drawingDimension drawing
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Reliability values according to EN ISO 13849-1
MGB2-L1... | Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (Closed-circuit current principle) |
Housing material | Fiber glass reinforced plastic, die-cast zinc, nickel plated |
Weight | |
Net | 1,0 kg |
Ambient temperature | |
At UB = 24V DC | -25 ... 55 °C |
Degree of protection | IP65 |
Resilience to vibration | In acc. with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Reaction time | See operating instructions for bus module MBM-... |
Switching frequency | 0,25 Hz |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Current consumption | max.350 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
EMC protection requirements | EMC directive 2014/30/EU |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Transponder coding | Unicode |
Power supply MLI | |
Operating voltage DC | |
MLI | 24 V DC -25% ... 15% |
Auxiliary voltage DC | |
MLI | 24 V DC -25% ... 15% |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 7.212 x 109 |
Diagnostic Coverage (DC) | 99 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 7.212 x 109 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |