- Safety switch without guard locking, with integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET 200 pro)
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With two plug connectors M12
- Unicode
- Emergency stop
- Approach directions A, B and C (delivery state)
Euchner CTP-I-AP-U-HA-ZZE-SBB-159614 CTP-I-AP safety switch without guard locking
SKU:
159614
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Connector assignment
Electrical connection ratings
Work area
Controls and indicators
Other
Reliability values according to EN ISO 13849-1
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | UB | Electronics operating voltage 24 V DC | BN | |
X 1.2 | FO1A | Safety output, channel 1 | WH | |
X 1.3 | 0 V UB | Electronics operating voltage 0 V | BU | |
X 1.4 | FO1B | Safety output, channel 2 | BK | |
X 1.5 | - | n.c. | GY | |
X 2.1 | S1.A1 | EMERGENCY STOP (channel A) | BN | |
X 2.2 | S1.B1 | EMERGENCY STOP (channel B) | WH | |
X 2.3 | - | n.c. | BU | |
X 2.4 | S1.A2 | EMERGENCY STOP (channel A) | BK | |
X 2.5 | S1.B2 | EMERGENCY STOP (channel B) | GY |
Housing material | |
Safety switch housing | Fiber glass reinforced thermoplastic |
Switch head cover | Die-cast zinc |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP65 |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin |
Approach speed | 20 m/min |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 1 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Emergency stop | |
Operating voltage | 5 ... 24 V |
Operating current | 1 ... 100 mA |
Repeat accuracy R | 10 % |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 2 pos. driven NC |
Detent mechanism | Snap-in bolt |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Emergency stop | |
B10D | 0,065 x 106 |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |