- Key adapter with integrated CES read head
- Integrated diagnostic LEDs
- Category 4/PL e according to EN ISO 13849-1
- Simple connection via AS-i
- High degree of protection IP 67
Euchner CKS-K-AS2A-U-C20-PC-123592 CKS key adapter
SKU:
123592
Categories: Sensors, Transponder-coded read heads with external evaluation
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Important: Keys must be ordered separately!
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
Dimensions | 40 x 75 x 32 |
Housing material | PA6-GF30 black |
Weight | |
Net | 0,13 kg |
Ambient temperature | -10 ... +65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Installation orientation | On the front |
Tightening torque | |
Fixing screws | 0,25 ... 0,35 Nm |
Connection | Screw terminal 2-pole |
ASi voltage | 19 ... 31,6 V |
ASi operating current | max.50 mA |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 2 |
Switch-on time | |
Safety outputs | max.300 ms |
ASi slave type | |
According to ASI specification 3.0 | EA code: 0 |
ID code: B | |
ASi data in | |
According to As-i Safety at Work | D2 |
D0 | |
D1 | |
D3 | |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Performance Level | PL e |
Category | 4 |
PFHD | 4.5 x 10-9 |
Mission time | 20 |