- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to category 4/PL e according to EN ISO 13849-1
- Multicode
- Approach direction A (default setting on delivery)
Euchner CET3-AS-CRA-CB-50X-1-116514 CET-AS safety switch with guard locking
SKU:
116514
Categories: Safety Switches, Safety switcheses and tools
Description
Additional information
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to [email protected] and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Guard locking type
Control of the guard locking solenoidThe guard locking solenoid is controlled by the control system via ASInterface bus bit D0.
AS-Interface inputs
Evaluation is performed via a safety monitor.
AS-Interface outputs
LED function display
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
CET3 | Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0. |
D0, D1 | Door monitoring |
D2, D3 | Guard lock monitoring |
D0 | Guard locking |
D1 | Red LED |
D2 | Green LED |
- The ASI LED indicates the operating voltage on the bus.
- The State LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Y | ±5 mm |
Z | ±4 mm |
X | ±5 mm |
Switching frequency | max.0,5 Hz |
Connection | |
1x | Plug connector M12 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
ASi address | 0 |
ASi voltage | 30 V 22,5 ... 31,6 V |
ASi operating current | 50 mA |
ASi auxiliary voltage | |
IEC 60742, PELV | 24 V -15% ... +10% |
ASi auxiliary current | 480 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
ASi slave type | |
According to ASI specification 2.1 | EA code: 7 |
ID code: B | |
ASi data in | |
According to As-i Safety at Work | D0 |
D1 | |
D2 | |
D3 | |
ASi data out | |
Guard locking solenoid | D0 |
LED red | D1 |
LED green | D2 |
ASi LED | |
LED red | Fault |
LED green | Power |
Safety class | |
EN IEC 61140 | III |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Mission time | 20 y |